MI 8 interface converts signals from Renishaw's rigid wire probes via a voltage-free solid state relay (SSR) and transmits them to the CNC station control.

  • Supply voltage 15 to 30V dc maximum
  • Supply voltage 16,5 to 28,5V with 3V peak to peak
    (with ripple) ripple at 100 Hz.
  • Supply current 50mA nominal.
  • Supply protection 80mA (T) anti-surge fuse (FS1).
  • Probe input Normally closed, open for trigger.
  • MI 8 output Voltage free - solid state relay (SSR)
    Normally open (N/O) or normally
    closed (N/C), selected by switch SW1.
    Maximum current 50mA peak.
    Maximum voltage ±50V peak.
  • Environment Storage temperature range
    -10° to 70°C (14° to 158°F).
    Operating temperature range
    5° to 50°C (41° to 122°F).