CI 42051
Rating : 6
| Evaluation | N. Experts | Evaluation | N. Experts |
|---|---|---|---|
| 1 | 6 | ||
| 2 | 7 | ||
| 3 | 8 | ||
| 4 | 9 | ||
| 5 | 10 |
16 pts from A_Partyns
| Sign up to vote this object, vote his reviews and to contribute to Tiiips.Evaluate | Where is this found? |
| "Patent blue studi" about CI 42051 Review Consensus 16 by A_Partyns (13048 pt) | 2020-Nov-08 18:53 |
| Read the full Tiiip | (Send your comment) |

Alcuni tra gli studi più significativi sull'impiego del colorante CI 42051 utilizzato in medicina ed in alimentazione.
Safety and efficacy of computed tomography-guided dye localization using patent blue V for single lung nodule for video-assisted thoracoscopic surgery: a retrospective study.
Chen JR, Tseng YH, Lin MW, Chen HM, Chen YC, Chen MC, Lee YF, Chen JS, Chang YC.
Ann Transl Med. 2019 Jan;7(2):28. doi: 10.21037/atm.2019.01.27.
Novel use of Patent Blue V dye to facilitate repair of lymph leak after groin debridement.
Hariswamy S, Lambrakis P.
ANZ J Surg. 2018 Apr;88(4):386-387. doi: 10.1111/ans.14425
Antiplasmodial activities of dyes against Plasmodium falciparum asexual and sexual stages: Contrasted uptakes of triarylmethanes Brilliant green, Green S (E142), and Patent Blue V (E131) by erythrocytes.
Leba LJ, Popovici J, Estevez Y, Pelleau S, Legrand E, Musset L, Duplais C.
Int J Parasitol Drugs Drug Resist. 2017 Dec;7(3):314-320. doi: 10.1016/j.ijpddr.2017.07.002
A prospective randomized trial comparing patent blue and methylene blue for the detection of the sentinel lymph node in breast cancer patients.
Paulinelli RR, Freitas-Junior R, Rahal RM, Oliveira LF, Vilela MH, Moreira MA, Alves KL, Peleja MB, Resende TC.
Rev Assoc Med Bras (1992). 2017 Feb;63(2):118-123. doi: 10.1590/1806-9282.63.02.118.
A Case of Anaphylaxis to Patent Blue in a Patient with Sentinel Lymph Node Excision.
Aurich S, Seitz AT, Tomm J, Simon JC, Treudler R.
Iran J Allergy Asthma Immunol. 2016 Dec;15(6):547-550
Blue dye for identification of sentinel nodes in breast cancer and malignant melanoma: a systematic review and meta-analysis.
Peek MC, Charalampoudis P, Anninga B, Baker R, Douek M.
Future Oncol. 2017 Feb;13(5):455-467. doi: 10.2217/fon-2016-0255
Patent blue V and indocyanine green for fluorescence microimaging of human peritoneal carcinomatosis using probe-based confocal laser endomicroscopy.
Abbaci M, Dartigues P, De Leeuw F, Soufan R, Fabre M, Laplace-Builhé C.
Surg Endosc. 2016 Dec;30(12):5255-5265
The Nordic SentiMag trial: a comparison of super paramagnetic iron oxide (SPIO) nanoparticles versus Tc(99) and patent blue in the detection of sentinel node (SN) in patients with breast cancer and a meta-analysis of earlier studies.
Karakatsanis A, Christiansen PM, Fischer L, Hedin C, Pistioli L, Sund M, Rasmussen NR, Jørnsgård H, Tegnelius D, Eriksson S, Daskalakis K, Wärnberg F, Markopoulos CJ, Bergkvist L.
Breast Cancer Res Treat. 2016 Jun;157(2):281-294. doi: 10.1007/s10549-016-3809-9
Anaphylactic reaction to patent blue V used in preoperative computed tomography-guided dye localization of small lung nodules.
Wu TT, Chang YC, Lee JM, Hung MH.
J Formos Med Assoc. 2016 Apr;115(4):288-9. doi: 10.1016/j.jfma.2015.04.003
The effects of Patent Blue dye on peripheral and cerebral oxyhaemoglobin saturations.
Ishiyama T, Kotoda M, Asano N, Ikemoto K, Mitsui K, Sato H, Matsukawa T, Sessler DI.
Anaesthesia. 2015 Apr;70(4):429-33. doi: 10.1111/anae.12932. Epub 2014 Nov 10.
| Sign up to vote this object, vote his reviews and to contribute to Tiiips.EvaluateClose | (0 comments) |
| "Impieghi del colorante CI 42051 o E" about CI 42051 Review Consensus 15 by A_Partyns (13048 pt) | 2020-Nov-08 18:54 |
| Read the full Tiiip | (Send your comment) |
Il CI 42051 è un colorante blu che viene identificato con una grande varietà di sinonimi.
Vedere anche CI 42051 Descrizione
Viene usato, in varie percentuali, in campo alimentare, medico, in cosmesi (nella preparazione di creme, detergenti, shampoo ecc.).

In campo medico serve come colorante vitale linfatico da iniettare in soluzione al 2,5% al fine di migliorare il tasso di identificazione di eventuali linfonodi sentinella (1).
Il Patent blue V (PBV) e il suo isomero Isosulfan blu (IB) vengono ottenuti da Patent blue o dal colorante Sulfan blu. Sia PBV che IB mostrano il tropismo linfatico e vengono quindi usati nelle biopsie dei linfonodi sentinella (SLNB). I gruppi europei usano PBV mentre gli americani usano IB, i 2 coloranti hanno un'alta reattività crociata. La prevalenza delle reazioni allergiche al PBV è compresa tra lo 0,34% e lo 0,5%, ma uno studio britannico ha riportato una prevalenza del 6% per anafilassi intraoperatoria legata al PBV. La prevalenza segnalata delle reazioni allergiche a IB varia tra 1% e 2% (2).
In campo alimentare è stato autorizzato dalla Direttiva Europea 78/25/EEC del 12/12/1977 col nome di Patent Blu V
Due dei gruppi di esperti scientifici dell’EFSA sono giunti alla conclusione che il colorante blu patentato V (E 131) non dà adito a preoccupazioni per la sicurezza di persone o animali, se impiegato come additivo alimentare o per mangimi ai livelli di utilizzo correnti. In base alla legislazione dell’UE in materia di alimenti e mangimi, l’EFSA è tenuta a operare secondo quadri normativi diversi, con requisiti distinti in materia di dati. (3).
Per quanto riguarda la sicurezza alimentare di questo colorante potete approfondire con questi testi (4).
Formula molecolare C54H62CaN4O14S4
Peso molecolare : 1159.43
CAS : 3536-49-0
Sinonimi :
e inoltre : Blue ZN 3, sulfan blue, sulphan blue, disulphine blue, disulfine blue, Carmine Blue V, Acidal Carmine V, Merantine Blue V, Alphazurine 2 G, NSC 5010, NSC 75430, EINECS 222-573-8, C.I. Food Blue 5, C.I. Acid Blue 3, Mitsui Acid Pure Blue VX, m-Hydroxytetraethyldiaminotriphenylcarbinol anhydride disulfonic acid calcium salt, Bis(hydrogen (4-(4-(diethylamino)-5'-hydroxy-2',4'-disulphonatobenzhydrylidene)cyclohexa-2,5-dien-1-ylidene)diethylammonium), calcium salt, Ethanaminium, N-(4-((4-(diethylamino)phenyl)(5-hydroxy-2,4-disulfophenyl)methyl- ene)-2,5-cyclohexadien-1-ylidene)-N-ethyl-, hydroxide, inner salt, calcium salt (2:1), N-(4-((4-(Diethylamino)phenyl)(5-hydroxy-2,4-disulfophenyl)methyl- ene)-2,5-cyclohexadien-1-ylidene)-N-ethylethanaminium, hydroxide, inner salt, calcium salt (2:1), Ethanaminium, N-(4-((4-(diethylamino)phenyl)(5-hydroxy-2,4-disulfophenyl)methylene)-2,5-cyclohexadien-1-ylidene)-N-ethyl-, inner salt, calcium salt (2:1), Ethanaminium, N-(4-((4-(diethylamino)phenyl)(5-hydroxy-2,4-disulfophenyl)methylene)-2,5-cyclohexadien-1-ylidene)-N-ethyl-, hydroxide, inner salt, calcium salt (2:1), calcium bis(4-{[4-(diethylamino)phenyl][4-(diethyliminio)cyclohexa-2,5-dien-1-ylidene]methyl}-6-hydroxybenzene-1,3-disulfonate), sodium 4-((4-(diethylamino)phenyl)(4-(diethyliminio)cyclohexa-2,5-dien-1-ylidene)methyl)benzene-1,3-disulphonate, ethanaminium, n-(4-((4-(diethylamino)phenyl)(2,4-disulfophenyl)methylene)-2,5-cyclohexadien-1-ylidene)-n-ethyl-, hydroxide, inner salt, sodium salt
Bibliografia_____________________________
(1) Preoperative lymphoscintigraphy and sentinel lymph node biopsy in papillary thyroid cancer. A pilot study.
Catarci M, Zaraca F, Angeloni R, Mancini B, de Filippo MG, Massa R, Carboni M, Pasquini G. J Surg Oncol. 2001 May,77(1):21-4, discussion 25.
The Nordic SentiMag trial: a comparison of super paramagnetic iron oxide (SPIO) nanoparticles versus Tc(99) and patent blue in the detection of sentinel node (SN) in patients with breast cancer and a meta-analysis of earlier studies.
Karakatsanis A, Christiansen PM, Fischer L, Hedin C, Pistioli L, Sund M, Rasmussen NR, Jørnsgård H, Tegnelius D, Eriksson S, Daskalakis K, Wärnberg F, Markopoulos CJ, Bergkvist L.
Breast Cancer Res Treat. 2016 Jun,157(2):281-294. doi: 10.1007/s10549-016-3809-9. Epub 2016 Apr 27.
Sentinel lymph-node biopsy in breast cancer: five years' experience.
Gioffrè Florio MA, Famà F, Gullo G, Pollicino A, Scarfò P. Chir Ital. 2004 Jan-Feb,56(1):107-12. Italian.
PMID: 15038655
(2) Allergy to Blue Dye.
Martín-Lázaro J, Núñez-Orjales R, Battikhi-Precedo N, López-Freire S, Carballada-González F.
J Investig Allergol Clin Immunol. 2016,26(6):381-383. doi: 10.18176/jiaci.0101
(3) Gli scienziati dell’EFSA incrementano ulteriormente il coordinamento nelle valutazioni di additivi alimentari e per mangimi - EFSA 1 Marzo 2013
(4) Sax's dangerous properties of industrial materials pagina 58 e pagina 935
Richard J. Lewis, Newton Irving Sax
John Wiley & Sons, 2000 - 1900 pagine
Human Toxicology of Chemical Mixtures - Harold Zeliger - pag.138
| Sign up to vote this object, vote his reviews and to contribute to Tiiips.EvaluateClose | (0 comments) |
![]() | "Descrizione" about CI 42051 Review Consensus 19 by Anonymous | 2024-May-23 19:45 |
| Read the full Tiiip | (Send your comment) |
CI 42051 è un composto chimico, un colorante sintetico, trifenilmetanico, Il trifenilmetano è un idrocarburo dal colore blu scuro. E' conosciuto anche come Patent blue V, Acid blue 3.
Processo di sintesi chimica industriale:
Forma e Colore
Il Blu di Brevetto V si presenta tipicamente come una polvere fine di colore blu intenso.

A cosa serve e dove si usa
Alimentazione
E' etichettato col numero E131 nella lista degli additivi coloranti europei.
Cosmetica
Colorante blu
Medicina
Imaging medico nel monitoraggio sanitario
Sicurezza
Due tra i gruppi di esperti scientifici dell’EFSA sono giunti alla conclusione che il colorante Patent blue V (E131) non dà adito a preoccupazioni per la sicurezza di persone o animali, se impiegato come additivo alimentare o per mangimi ai livelli di utilizzo correnti. In base alla legislazione dell’UE in materia di alimenti e mangimi, l’EFSA è tenuta a operare secondo quadri normativi diversi, con requisiti distinti in materia di dati. Anche dal punto di vista genotossico non è stata rilevata alcun effetto.
Tuttavia diversi studi hanno constatato casi di allergia a questo colorante (1).
Formula molecolare: C27H31N2O7S2Na (sale di sodio)
CAS: 20262-76-4
EC Number: 243-654-4
oppure
Formula molecolare: C27H31N2O7S2Ca (sale di calcio)
CAS: 3536-49-0
Peso molecolare: 1159.422 g/mol
UNII: 8QE473DV1Z
EC Number: 222-573-8
Sinonimi:
Bibliografia_____________________________________________________________________
(1) Vidya R, Athwal R, Huissoon AP, Baretto RL, Thirumala Krishna M. Diagnostic application of patent blue V in sentinel lymph node biopsy for breast cancer - Is it time for a change? Indian J Cancer. 2019 Jul-Sep;56(3):269-270. doi: 10.4103/ijc.IJC_139_18. PMID: 31389393.
Abstract. Sentinel lymph node biopsy (SLNB) was introduced in the 1990s, as a minimally invasive procedure for staging the axilla with less morbidity to the traditional axillary lymph node dissection and is now standard management of the axilla in the early breast cancer. SLNB using the combined technique of blue dye and radioisotope is currently the recommended method for lymphatic mapping, and studies have shown high identification rates (IR) (>95%) and low false-negative rates (FNR) 5-10%. However, there are several reports raising awareness regarding patent blue V dye-induced peri-operative anaphylaxis. The main aim of this article is to highlight the emergence of patent blue dye as a new allergen and present evidence regarding the utility of alternative safer methods of evaluation of early breast cancer without compromising IR.
Misir Šitum S, Korečić Zrinjščak I, Pečvarac M, Šoštar A, Žaja A, Tot T. Case report: Atypical anaphylactic reaction to Patent Blue V dye during breast cancer surgery. Front Oncol. 2022 Sep 16;12:979393. doi: 10.3389/fonc.2022.979393.
Costa D, Mendonça M, Lopes M, Fernandes AL, Nunes S, Müller S. Anafilaxia por corante azul patente V: relato de caso e revisão da literatura [Patent blue V dye anaphylaxis: a case report and literature review]. Braz J Anesthesiol. 2020 Nov-Dec;70(6):662-666. doi: 10.1016/j.bjan.2020.05.005.
| Sign up to vote this object, vote his reviews and to contribute to Tiiips.EvaluateClose | (0 comments) |
Read other Tiiips about this object in English (3)
Component type:   Chemical Main substances:   Last update:   2023-01-22 15:44:54 | Chemical Risk:   |